Our stainless steel watches case and band are from the environmental raw-materials. They are approved to be the eco-friendly and not harmful to human beings. The stainless steel materials are passed by RoHS and REACH testing by SGS. The below pictures are the conclusions of testing for 304/316L stainless steel materials. The test reports are the latest in 2017.
As to stainless steel watches, there are 2types of stainless steel raw-materials chosen by watch dealers. They 304 stainless steel and 316L stainless steel.
Currently, most of minimalist watches are made of stainless steel case and our products are not harm to end-users.
What can be stainless steel applied to?
types: women watches, men watches, unisex watch, gift watches
functions: analog watches, chronograph watches, automatic mechanical watches, diving watches
304 stainless steel test reports.
316L stainless steel test reports
Test Report. No. CANML1625831801 Date: 03 Jan 2017. Page 1 of 4.
SHENZHEN YONG JI STEEL CO., LTD.
NO.1, MIN SHENG ROAD 4, LIAO KENG VILLAGE, SHI YAN STREET, BAO AN DISTRICT, SHEN ZHENG
CITY
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : 304 STAINLESS
STEEL.
SGS Job No. :
SZIN1612017092PC - SZ.
Date of Sample Received :.
28
Dec 2016.
Testing Period :.
28
Dec 2016 - 03 Jan 2017.
Test Requested :.
Selected test(s) as requested by client..
Test Method :.
Please refer to next page(s)..
Test Results :.
Please refer to next page(s)..
Conclusion :.
Based on the performed tests on submitted sample(s), the results of Lead,
Mercury, Cadmium, Hexavalent chromium comply with the limits as set by RoHS
Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. .
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Merry Lv.
Approved Signatory.
Test Report. No. CANML1625831801 Date: 03 Jan 2017. Page 2 of 4.
Test Results :.
Test Part Description :.
Specimen No.. SGS Sample ID. Description.
SN1. CAN16-258318.001 Silver-grey metal board.
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001%.
(2) MDL = Method Detection Limit.
(3) ND = Not Detected ( < MDL ).
(4) "-" = Not Regulated.
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Test Method :. (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES. (2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321-7-1:2015 , determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis..
Test Item(s).
Limit.
Unit.
MDL.
001.
Cadmium (Cd).
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
ND
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (Cr(VI))▼.
-.
µg/cm².
0.10
ND
Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(2) ▼= a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm2. The
sample coating is considered to contain CrVI
b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm2). The coating is considered a non-CrVI based coating
c. The result between 0.10 μg/cm2 and 0.13 μg/cm2 is considered to be inconclusive - unavoidable coating variations may influence the determination
Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results represent status of the sample at the time of testing.
IEC 62321 series is equivalent to EN 62321 series http://www.cenelec.eu/dyn/www/f? p=104:30:1742232870351101::::FSP_ORG_ID, FSP_LANG_ID:1258637,25.
Test Report. No. CANML1625831801 Date: 03 Jan 2017. Page 3 of 4.
ATTACHMENTS
Pb/Cd/Hg/Cr6+ Testing Flow Chart
1) Name of the person who made testing: Edith Zhang
2) Name of the person in charge of testing: Bella Wang
3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr6+ test method excluded)
Pb/Cd/Hg
Acid digestion with microwave/ hotplate
Filtration
Solution
Residue
1) Alkali Fusion /
Dry Ashing 2) Acid to
dissolve
ICP-OES/AAS
DATA
Sample Preparation
Sample Measurement
Nonmetallic
material
Adding digestion
reagent
Heating to
90~95℃ for extraction
Filtration and
pH adjustment
Adding 1,5-diphenylcarbazide for color development
UV-Vis
DATA
Cr6+
Metallic material
Boiling water
extraction
Adding 1,5-diphenylcarbazide for color development
UV-Vis
DATA
Test Report. No. CANML1625831801 Date: 03 Jan 2017.
Sample photo:.
CANML1625831801
CAN16-258318.001.
SGS authenticate the photo on original report only.
*** End of Report ***.
Contact: Mark Wu
Phone: +86 13400645581
Tel: 0592-5613002
Email: info@radsenwatch.com
Add: No.10 Jinhua Rd, Xiangcheng, Zhangzhou, Fujian, China.